WS-GP2 Advanced Automatic Weather Station System

  • Powerful, rugged and highly flexible weather station
  • Designed for use in severe weather conditions
  • Wide choice of sensors, including soil moisture
  • Cellular modem communications
  • Compatible with DeltaLINK-Cloud online data sharing platform
  • Calculation of full Penman-Monteith evapotranspiration equation

Specification

GP2 Data Logger – Brief Specs

Input connections 12 differential (or 24 single-ended) analog inputs configurable as: Voltage, Resistance (12 3-wire or 24 2-wire), Bridge (12), Potentiometer (12)

4 digital inputs as: Counters, (2 fast + 2 slow), Frequency, Digital state

1 Delta-T WET sensor channel
Unlimited virtual channels

Serial input channel: 62 SDI-12 sensors or a single WET Sensor

Control outputs 2 relay outputs expandable to 6 (1 A)
Readings stored 2.5 Million
Recording rate 1 second to 24 hours
Configuration DeltaLINK
Communication options USB, RS232, ethernet or modem
Sensor excitation Calibrated 3V reference, +5 V and +12 V regulated, or 5 to 10.5 V (battery or external power), user selectable
Power 6 AA alkaline batteries or external power 10-15 V DC
Battery life (dependent on usage) >310K readings, lasting 530 days
Enclosure rating IP65
Temperature range -20 to +60°C
Display
Size 225 x 185 x 75 mm
Typical applications Demanding research projects
Environmental monitoring
Varied control applications

 

WS-GP2 Sensors – Brief Specs

Specification Range / Note
Wind speed AN-WD2 (combined wind sensor)
Range 0 to 75 m.s-1
Accuracy ± 0.1 m.s-1 Up to 10 m.s-1
± 1.1% of reading Over 10 m.s-1
Starting threshold 0.4 m.s-1 -30°C to +70°C if icing minimal
Wind direction AN-WD2 (combined wind sensor)
Accuracy ± 4° mechanical: 0 to 360°

electrical: 0 to 356°

Starting threshold 0.4 m.s-1 -30°C to +70°C (if icing minimal)
Rainfall RG2+BP
Sensitivity 0.2 mm per tip up to 360 mm.hr-1
Humidity RHT2nl (combined air temp sensor)
Accuracy ± 2% RH 5 to 95% RH
± 2.5% RH <5% and >95% RH
Air temperature RHT2nl (combined RH sensor)
Accuracy ± 0.1°C 0 to 70°C
Solar radiation ES2
Absolute accuracy ± 5% At 20°C (optimal conditions)
Linearity ± 1% 0 to 2 kW.m-2
Soil temperature ST1
Accuracy ± 0.2°C -10 to +65°C
Mast M2-FSG
2m mast With cross arm, stakes, steel guy wires, baseplate and logger canopy

Reviews

There are no reviews yet.

Be the first to review “WS-GP2 Advanced Automatic Weather Station System”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “WS-GP2 Advanced Automatic Weather Station System”

Your email address will not be published. Required fields are marked *